Get it Touch
Page title icon

Single product

InsightFlow – 12.8V 200Ah

Sh589.00

***Included 7-Year Warranty***

Product Specification

Model:      LiFePO4 12.8V 200Ah

MODEL NO.:        LT12-200

 

www.lumia-energy.com

 

No.

Item

General Parameter

Remark

1

Nominal Voltage

12.8V

2

Rated Capacity

200Ah

3

Cycle Life

≥6000 Cycles

Charge: CC@20A to 14.6V, then CV till current to 0.05C; Rest: 30min;

Discharge: 100A to 10.0V;

Temperature: 20±5℃.

4

Discharge Cut-off Voltage

10.0V

5

Charge Cut-off Voltage

14.6V

6

Material

LiFePO4

7

Recommend Charge Current

40A~50A

8

Max. Continuous Charge Current

100A

9

Max. Continuous Discharge Current

100A

Peak: 250A

10

Operation Temperature

Charge: 0~55℃

Discharge: -20~65℃

Storage: 0~45℃

11

Self-discharge Rate

<3%/month

12

Outer Case

ABS Plastic Case

13

Weight

Approx.: 25Kg

14

Dimension (L*W*H)

525*240*220mm(±2mm)

15

Bluetooth Function

Yes

16

Display Screen

Optional

2. Product Structure Design

Product appearance (for reference only)

 

3.Test conditions

All tests shall be done under temperature: 15℃~35℃, relative humidity: (RH)

25%~85%, air pressure: 86kPa~106kPa except special appointment.

Measuring apparatus

Voltage is measured by DC Voltmeter whose precision is higher than 0.5 grade

and self resistance is higher than 1kΩ/V;

Current is measured by Amperemeter whose precision is higher than 0.5 grade;

Temperature is measured by Thermometer which has proper measuring range and

its division value is lower than 0.5℃;

The time used in measuring should be degreed in hour, minute or second, and should have degree of accuracy no less than ±1%.

Standard charge

Charge the battery with DC stable power supply 14.6V, constant current 20A until current reach to 0.05C(A).

Standard discharge

Charge battery by (3-3), discharge the battery with constant current 100A until the battery reach to over discharge protection or total voltage reach to 10V.

Battery capacity

Discharge battery by (3-4), and write down discharge time (hour), then capacity (Ah)=100A * discharge time (hour).

Electrochemistry performance

Item

Test Method

Technical requirement

20℃ discharge capacity

Battery charge with standard methods, discharge at 100A, write down discharge capacity.

≥95% nominal capacity

55℃ discharge capacity

Battery charge with standard methods, stored for 5h in 55℃±2℃, then discharge at 100A to cut-off voltage, write down

discharge capacity.

≥80% nominal capacity

Charge retain ability

and recover capability

Battery charge with standard methods, stored for 28d in normal temperature 7d in 55℃.

capacity retention rate≥80% capacity recover rate≥90%

Cycle life

Under the condition of 20℃±5℃, charge

the battery with 0.2C(A); discharge the

battery at 100A to cut-off voltage. Repeat the above test cycle till the retained

capacity is 80% of initial capacity.

≥6000 cycles

 

4. Product Storage & Transportation

Storage

Transportation

Maintenance

If the battery pack needs to be stored for a long time,

charge the battery to 50% SOC (after discharge,

charge by charger

for 2~3h every 3 months).

Battery pack and the charger should be stored in a clean, dry and ventilating place,

and should not be placed together with corrosive

material, keep the battery away from fire and heat

source.

Battery pack and charger should be transported

after packaging, and should avoid severe vibrating,

impacting, extrusion, direct light and rain. They can be transported by automobile, train, ship, plane, etc..

state-of-charge.

maintenance, don’t assemble and disassemble the battery

without permission, otherwise, the performance of battery

will be descend.

The battery pack should be stored in 40%~60%

In the process of

5. Warnings

Do not immerse the battery into water or seawater.

Do not use, leave or charge the battery near a heat source such as fire or heater.

Do not inversely connect positive and negative polar.

Do not put the battery in fire or heat the battery.

Do not short-circuit the battery with wires or other metals.

Do not pierce the shell with nails or other sharp objects. Do not hammer or tread the pack.

Do not disassemble the battery pack without permission.

Do not put the battery pack in microwave oven or pressure vessels.

Do not use the battery in extremely thermal environment, such as direct light or cars in hot day. Otherwise, the battery will overheats and the performance and life of battery will be influenced.

If the battery leaks or smells, move it away from open fire.

The battery should be used after fully charged in the first use.

If the battery pack smells, fevers, out of shape, color changes or any other abnormal phenomena happen when the battery is being charged or used, please take it out of the charger or electrical equipment.

If the battery leaks and the electrolyte contacts eye, do not rub eye. Instead, rinse eye with clean water, and seek medical attention immediately.

*Temperature will influence discharge capacity, if the temperature exceeds standard environment

temperature (25±°5℃), discharge capacity will reduce.

2 reviews for InsightFlow – 12.8V 200Ah

  1. Rob

    I’ve been a fan of sustainable living for years and switching from Lead acid to LFP has been one of my best decisions.

    November 16, 2023
  2. Danny

    As an electrician, I’ve installed various batteries, but the Lumia’s product range stands out. It’s not just about the power—it’s the reliability and efficiency that make it my go-to recommendation.

    November 16, 2023
Add a review

Your email address will not be published. Required fields are marked *

Select your currency
TZS Tanzanian shilling